US RV solar and battery calculator for boondocking and off-grid camping
Pick a sample setup or build your own. Every result shows how it was calculated, and the battery, solar and gear suggestions update as you change anything.
Built for US RV, van and truck-camper owners. The planner uses US electrical guidance, AWG wire sizing and representative US solar and climate data. Here, boondocking means camping off-grid without normal campground utility hookups.
What is your setup?
Do not worry too much about choosing the perfect option. No matter which setup you choose, you can change the values, add or remove appliances, and adjust anything else in the calculator below.
Calculator inputs
Advanced
Idle draw: 20 W × 24 h = 0 Wh/day. Set 0 if you switch the inverter off when not in use.
Setup
- System
- 12 V
- Location
- Custom PSH
- Battery
- LiFePO4 · 200 Ah · 90 % DoD
- Solar
- 400 W · 4.5 PSH · MPPT
- Forecast
- Sunny / Partly cloudy / Sunny
Advanced
- Inverter efficiency
- 87 %
- Inverter idle draw
- 20 W × 24 h/day = 0 Wh
- DC converter efficiency
- 90 %
Appliances
- 12V compressor fridge — 45 W, 7.92 h/day (DC)
- Starlink Mini — 30 W, 12 h/day (DC)
Results
Solar surplus: 583 Wh/day
Stored 1,300 Wh vs use 716 Wh (56 Ah)
- Battery
- 2,560 Wh (2,304 usable)
- Battery-only runtime (no solar)
- 3.2 days
- Inverter
- None needed
- Suggested for 2 days
- 200 Ah and 300 W solar
| Load | At appliance | From battery |
|---|---|---|
| 12V compressor fridge | 356 Wh | 356 Wh |
| Starlink Mini | 360 Wh | 360 Wh |
Stays above the depth-of-discharge limit.
How this was calculated
Daily energy from battery
- DC loads: 716 Wh at appliance = 716 Wh from battery (native DC, no conversion)
- Total daily use: 716 Wh (56 Ah at 12.8 V)
Solar harvest
- Array 400 W × 4.5 peak sun hours = 1,800 Wh of sun on the array
- × panel derate 0.80 (heat, dust, angle) = 1,440 Wh at the panel output
- × charge controller efficiency 0.95 (MPPT) = 1,368 Wh into the battery path
- × battery charge efficiency 0.95 (LiFePO4) = 1,300 Wh stored
Net daily balance
- Total stored: 1,300 Wh
- Total used: 716 Wh
- Net: 583 Wh (Solar surplus)
Full formulas, constants and changelog: methodology. Battery-only runtime uses 2,304 Wh usable (bank 2,560 Wh × 0.90 DoD).
What to buy
Battery
Matches the recommended 12V 200 Ah LiFePO4 bank.
Mini Size 12V 200Ah LiFePO4 Battery w/ Low-Temperature Protection
Renogy
Low-temperature charge protection noted
Single 200Ah battery with a 200A BMS and low-temperature charge and discharge protection.
Solar Panels
Matches the recommended 300 W array size.
3 × 100W N-Type Solar Panels
Renogy
Three identical 100W panels for a nominal 300W array. Verify roof space, controller limits and series/parallel wiring before installation.
Charge Controller
Meets or exceeds the calculated 40 A minimum controller rating for the 400 W array on a 12V system.
SmartSolar MPPT 100/50
Victron Energy
50A MPPT solar charge controller for 12V or 24V systems. Used when the calculated minimum is above the 30A model's rating.
Portable Alternative
A plug-and-play alternative for users who prefer a portable power station instead of wiring a custom battery, solar and inverter system.
HomePower 1000 Plus v2
Jackery
Portable LiFePO4 power station with approximately 1,024Wh capacity and 1,800W rated AC output; a plug-and-play alternative to a permanently wired RV system.
No prices are shown because prices change. Always confirm current specifications, manual, warranty and installation requirements before buying. Planning guidance only. Verify compatibility, wiring, fusing, battery limits and installation requirements with the manufacturer and a qualified RV electrician. See the disclaimer.
Planning estimate only. Not engineering advice. Verify all wiring and battery sizing with a qualified RV electrician; follow applicable NEC and NFPA 1192 requirements and the relevant manufacturer instructions. Method: /methodology/. Full terms: /disclaimer/.
Sample RV power setups compared
| Setup | Where and when | Daily use | Battery for 2 days | Solar needed |
|---|---|---|---|---|
| Starlink Mini + 12V fridge off-grid | Generic site (4.5 peak sun hours) | 716 Wh | 200 Ah | 300 W |
| CPAP off-grid overnight | Generic site (4.5 peak sun hours) | 380 Wh | 100 Ah | 200 W |
| Residential fridge on an inverter | Generic site (4.5 peak sun hours) | 1,683 Wh | 300 Ah | 600 W |
| All-12V minimalist van | Generic site (4.5 peak sun hours) | 985 Wh | 200 Ah | 400 W |
| Rooftop A/C on solar and lithium | Las Vegas, NV, July, tilted panels | 4,295 Wh | 800 Ah | 900 W |
| Weekend warrior van power setup | Generic site (4.5 peak sun hours) | 669 Wh | 200 Ah | 300 W |
| Full-time remote work RV | Quartzsite, AZ, January, tilted panels | 2,780 Wh | 600 Ah | 800 W |
| 400W solar + 200Ah lithium | Quartzsite, AZ, January, tilted panels | 816 Wh | 200 Ah | 300 W |
| 800W solar + 400Ah lithium | Quartzsite, AZ, January, tilted panels | 2,211 Wh | 400 Ah | 600 W |
| Weekend trips: 100Ah battery + 200W solar | Austin, TX, June, flat panels | 669 Wh | 200 Ah | 200 W |
| Quartzsite winter boondocking (Arizona snowbird) | Quartzsite, AZ, January, tilted panels | 1,056 Wh | 200 Ah | 300 W |
| Winter furnace boondocking (Flagstaff, cold-charge limits) | Flagstaff, AZ, January, tilted panels | 796 Wh | 200 Ah | 300 W |
| Pacific Northwest cloudy-weather RV solar (Seattle, December) | Seattle, WA, December, tilted panels | 745 Wh | 200 Ah | 700 W |
Battery is 12V LiFePO4 sized for two days with no solar input; solar is sized to cover the daily use with an MPPT charge controller. Values are planning estimates from the same engine as the calculator. How these are calculated.
Frequently asked questions
How is daily energy use calculated?
Each appliance contributes watts times hours per day. AC loads are divided by the inverter efficiency, converter loads by the converter efficiency, and an inverter idle draw is added whenever any AC load is present. The full formulas are on the methodology page.
Can I charge a LiFePO4 battery in freezing weather?
Standard LiFePO4 batteries must not be charged below 0 °C (32 °F). Choose a battery with a low-temperature charge cut-off or self-heating, or keep it in a heated space. The calculator warns you when the selected region and month have freezing nights.
Why does a rooftop A/C trigger a high-current warning on 12 V?
A large AC load on a 12 V battery bank draws a very high DC current through the inverter cables. Heavy cable, a correctly rated fuse and short runs are essential, and a 24 V or 48 V system reduces the current considerably.
Where do the sun-hour figures come from?
They are monthly values from NLR PVWatts v8 for 15 representative US locations, for flat and tilted panels, with a fixed system loss. Real output varies with shading, dirt and temperature.